{"id":7579,"date":"2023-08-26T07:46:22","date_gmt":"2023-08-25T22:46:22","guid":{"rendered":"https:\/\/www.dry-fog.com\/en\/?post_type=technical-report&#038;p=7579"},"modified":"2025-03-05T13:21:42","modified_gmt":"2025-03-05T04:21:42","slug":"basics-009","status":"publish","type":"technical-report","link":"https:\/\/www.dry-fog.com\/en\/projects-technology\/technical-report\/basics-009\/","title":{"rendered":"Basics of Spray Nozzles | Turn-Down and Air-Water Ratio | Features of Pneumatic Spray Nozzles"},"content":{"rendered":"<p><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\">Pneumatic spray nozzles atomize liquids, utilizing high-velocity fluid flow, such as compressed air. <\/span><\/p>\n<p align=\"center\"><img decoding=\"async\" src=\"https:\/\/www.dry-fog.com\/en\/wp-content\/uploads\/sites\/3\/2025\/02\/basics-009_1.png\" alt=\"pneumatic spray nozzle\" width=\"600\" \/><\/p>\n<div style=\"margin-bottom: 0.1rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/10px-45px.svg') no-repeat 0 0;background-size: auto 30px;padding-left: 20px\">\n<h3 style=\"font-size: 1.3rem\"><span style=\"font-family: arial, helvetica, sans-serif\">Advantages of Pneumatic Spray Nozzles<\/span><\/h3>\n<p><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\">Compared to hydraulic spray nozzles driven only by a pump, pneumatic spray nozzles have the following advantages. <\/span><\/p>\n<div><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\"> <span style=\"font-weight: bold;font-size: 1.2rem\"><u>Excellent atomizing performance:<\/u><\/span><br \/>\nPneumatic spray nozzles are capable of producing fine atomization with a mean droplet diameter of 10 \u03bcm or less.<\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\"><br \/>\n<span style=\"font-weight: bold;font-size: 1.2rem\"><u>Large turn-down ratio:<\/u><\/span><br \/>\nPneumatic spray nozzles have a large turn-down ratio of spray flow rate* with little variation in spray droplet size and flow distribution, which makes them ideal for spray flow adjustable nozzles.<br \/>\n*Spray flow rate is expressed as spray capacity in our catalogs.<\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\"><br \/>\n<span style=\"font-weight: bold;font-size: 1.2rem\"><u>Large free passage diameter:<\/u><\/span><br \/>\nPneumatic spray nozzles have a larger <a style=\"color: #00a273\" href=\"https:\/\/d2ca4eea.viewer.kintoneapp.com\/public\/ikeuchi-faq-en\/detail\/def50200cbb1b1c7fd15a9b85f9489f69011cffa72c7210bc7cbdcd54a29fe6d89f6e68f7b394d9ff4f5e9a1920af14fa1a2afc47344f268661fe88747020c6d1f5fe6736e6c8be1679fbac0f440c62a7edf7bc841a98dac555e472b1bbcebabc45092a7cc\" target=\"_blank\" rel=\"noopener\">free passage diameter<\/a> than hydraulic spray nozzles, which helps reduce nozzle-clogging problems. <\/span><\/div>\n<div style=\"margin-bottom: 0.1rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/10px-45px.svg') no-repeat 0 0;background-size: auto 30px;padding-left: 20px\">\n<h3 style=\"font-size: 1.3rem\"><span style=\"font-family: arial, helvetica, sans-serif\">Pneumatic Nozzle Application Examples<\/span><\/h3>\n<\/div>\n<p align=\"center\"><img decoding=\"async\" src=\"https:\/\/www.dry-fog.com\/en\/wp-content\/uploads\/sites\/3\/2025\/02\/basics-009_2w1200.png\" alt=\"application examples for pneumatic nozzles\" width=\"1100\" \/><\/p>\n<div style=\"margin-bottom: 0.1rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/10px-45px.svg') no-repeat 0 0;background-size: auto 30px;padding-left: 20px\">\n<h3 style=\"font-size: 1.3rem\"><span style=\"font-family: arial, helvetica, sans-serif\">What is Turn-Down for Spray Nozzles?<\/span><\/h3>\n<\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\">The turn-down range refers to the adjustable range of spray capacity, and the ratio of its minimum to maximum spray capacity is called the turn-down ratio.<br \/>\n<span style=\"font-weight:bold;font-size: 1.2rem\">A large turn-down ratio means that a single nozzle can cover a wide range of spray capacities, from small to large<\/span>.<\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\"><br \/>\nThe spray capacity of hydraulic spray nozzles is proportional to the square root of the pressure, meaning the turn-down range is limited. To cover a wide range of spray capacities with a hydraulic spray nozzle, a large increase or decrease in operating pressure is required, which is not practical.<\/div>\n<div><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\"><br \/>\nOn the other hand, pneumatic spray nozzles can be adjusted in both air and liquid pressures, enabling wide spray capacity adjustments with minimal changes in pressure.<br \/>\nThe green and orange arrows in the figure below indicate the respective turn-down ranges of a hydraulic spray nozzle and a pneumatic spray nozzle under the same liquid pressure range.<br \/>\n <\/span><\/div>\n<p align=\"center\"><img decoding=\"async\" src=\"https:\/\/www.dry-fog.com\/en\/wp-content\/uploads\/sites\/3\/2025\/02\/basics-009_3-turn-down.png\" width=\"600\" \/><\/p>\n<div><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\"><br \/>\nTherefore, pneumatic spray nozzles are ideal for cooling combustion gases and other applications that require nozzles with small droplet sizes and large turn-down ratios. Such nozzle series include the <a href=\"https:\/\/www.dry-fog.com\/en\/products\/noz-pne-dovea\/\" style=\"color: #00a273\" target=\"_blank\" rel=\"noopener\">DOVEA<\/a>, <a href=\"https:\/\/www.dry-fog.com\/en\/products\/noz-pne-dda\/\" style=\"color: #00a273\" target=\"_blank\" rel=\"noopener\">DDA<\/a>, and <a href=\"https:\/\/www.dry-fog.com\/en\/products\/noz-pne-jja\/\" style=\"color: #00a273\" target=\"_blank\" rel=\"noopener\">JJA<\/a> series. <\/div>\n<div style=\"margin-bottom: 0.1rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/10px-45px.svg') no-repeat 0 0;background-size: auto 30px;padding-left: 20px\">\n<h3 style=\"font-size: 1.3rem\"><span style=\"font-family: arial, helvetica, sans-serif\">What is Air-Water Ratio?<\/span><\/h3>\n<div><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\">Air-water ratio is the rate of air consumption divided by spray capacity.<br \/>\nThe ratio can be expressed in both volume and weight ratios. <span style=\"font-weight:bold;font-size: 1.2rem\">For the same nozzle, a higher air-water ratio will result in a smaller spray droplet size<\/span>.<br \/>\nThe air-water ratio in <a href=\"https:\/\/we.kinkosonline.jp\/html\/kirinoikeuchi\/7663333\/\" style=\"color: #00a273\" target=\"_blank\" rel=\"noopener\">our pneumatic spray nozzle catalog<\/a> is expressed as the volume ratio unless otherwise specified.<br \/>\n<\/span><\/div>\n<p><\/p>\n<p align=\"center\"><img decoding=\"async\" src=\"https:\/\/www.dry-fog.com\/en\/wp-content\/uploads\/sites\/3\/2025\/02\/basics-009_4air-water_ratio.png\" width=\"600\" \/><\/p>\n<p style=\"text-align: left\"><span style=\"font-family: arial, helvetica, sans-serif;font-size: 14pt\"><br \/>\nRelated FAQ: <a href=\"https:\/\/d2ca4eea.viewer.kintoneapp.com\/public\/ikeuchi-faq-en\/detail\/def502002c98bf34aba8c2b7a0ea5ed5294c253ab6b28a9d64d60d42ab7df917d2820e4255f2372fbcfcfae991363444316cadf782add44158da12d6bbd8fed69a70b5cb3477dba600af5ef1c4a18d8ad4f0f235ef0672d1ed7704298b3eed61a0c404e963\" style=\"color: #00a273\" target=\"_blank\" rel=\"noopener\">What are Pneumatic Spray Nozzles? <\/a><\/p>\n","protected":false},"featured_media":0,"template":"","cat_technical_report":[551],"tag_technical_report":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/technical-report\/7579"}],"collection":[{"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/technical-report"}],"about":[{"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/types\/technical-report"}],"wp:attachment":[{"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/media?parent=7579"}],"wp:term":[{"taxonomy":"cat_technical_report","embeddable":true,"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/cat_technical_report?post=7579"},{"taxonomy":"tag_technical_report","embeddable":true,"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/tag_technical_report?post=7579"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}