{"id":8650,"date":"2025-11-06T08:00:36","date_gmt":"2025-11-05T23:00:36","guid":{"rendered":"https:\/\/www.dry-fog.com\/en\/?post_type=technical-report&#038;p=8650"},"modified":"2025-11-08T00:08:47","modified_gmt":"2025-11-07T15:08:47","slug":"hum-smt-005","status":"publish","type":"technical-report","link":"https:\/\/www.dry-fog.com\/en\/projects-technology\/technical-report\/hum-smt-005\/","title":{"rendered":"Seasonal Swings and Static: How SMT Yields Drop When Humidity Drops"},"content":{"rendered":"<div class=\"text2 first\">\n<section>\n<div style=\"max-width: 824px;margin-left: auto;margin-right: auto\">\n<div style=\"margin-bottom: 0.8rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/10px-45px.svg') no-repeat 0 0;background-size: auto 30px;padding-left: 20px\">\n<h3 style=\"font-size: 1.5rem\">Intro<\/h3>\n<\/div>\n<p><span style=\"font-weight: 400;font-size: 14pt\">For electronics manufacturers, maintaining consistent yield and quality on surface-mount technology (SMT) lines can feel like walking a tightrope, especially during seasonal shifts. Winter months often bring dry indoor air, which can lead to a subtle but significant challenge, static electricity buildup.<\/span><\/p>\n<div class=\"text2 first\">\n<section>\n<div style=\"max-width: 824px;margin-left: auto;margin-right: auto\">\n<div style=\"margin-bottom: 0.8rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/10px-45px.svg') no-repeat 0 0;background-size: auto 30px;padding-left: 20px\">\n<h3 style=\"font-size: 1.5rem\">Understanding the Risk<\/h3>\n<\/div>\n<p><span style=\"font-weight: 400;font-size: 14pt\">Low humidity environments, typically below 45% relative humidity at 68\u00b0F (20\u00b0C), can create conditions where static charges accumulate rapidly on sensitive components. In SMT processes, this can manifest as<\/span><\/p>\n<ul style=\"list-style-type: disc;margin-left:2.8rem;font-size: 14;1rem;line-height:1.5rem\">\n<span style=\"font-size: 14pt\"><\/p>\n<div style=\"margin-bottom:0.5rem\">\n<li>Pick-and-place errorsL: Tiny electrostatic charges can alter the trajectory of lightweight components, causing misalignment or placement issues.<\/li>\n<\/div>\n<p><\/span><br \/>\n<span style=\"font-size: 14pt\"><\/p>\n<div style=\"margin-bottom:0.8rem\">\n<li>Solder paste handling problems: Dry air can contribute to uneven paste deposition or clumping, impacting reflow consistency.<\/li>\n<\/div>\n<p><\/span><br \/>\n<span style=\"font-size: 14pt\"><\/p>\n<div style=\"margin-bottom:0.8rem\">\n<li>Increased inspection and rework requirements:Even minor static events can trigger errors detectable only during automated optical inspection (AOI) or in later testing, adding to production time and cost.<\/li>\n<\/div>\n<p><\/span>\n<\/ul>\n<p><span style=\"font-weight: 400;font-size: 14pt\">These challenges are not new, but their impact grows as boards become more complex and components more densely packed. Recognizing and mitigating environmental factors is critical to maintaining throughput and quality.<\/span><\/p>\n<div class=\"text2 first\">\n<section>\n<div style=\"max-width: 824px;margin-left: auto;margin-right: auto\">\n<div style=\"margin-bottom: 0.8rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/10px-45px.svg') no-repeat 0 0;background-size: auto 30px;padding-left: 20px\">\n<h3 style=\"font-size: 1.5rem\">Precision Humidity Control: A Targeted Approach<\/h3>\n<\/div>\n<p><span style=\"font-size: 14pt\"><span style=\"font-weight: 400\">One effective strategy for managing static is the use of <\/span><b>precision dry fog humidification<\/b><span style=\"font-weight: 400\">, such as Ikeuchi\u2019s AKIMist\u00aeE system. Unlike conventional humidifiers, dry fog delivers ultrafine droplets that mix uniformly into the airflow without wetting surfaces or creating condensation. This provides several operational advantages<\/span><\/span><\/p>\n<ul style=\"list-style-type: disc;margin-left:2.8rem;font-size: 14;1rem;line-height:1.5rem\">\n<span style=\"font-size: 14pt\"><\/p>\n<div style=\"margin-bottom:0.5rem\">\n<li>Stable, uniform humidity: By maintaining controlled relative humidity, the risk of electrostatic buildup is minimized across the production floor.<\/li>\n<\/div>\n<p><\/span><br \/>\n<span style=\"font-size: 14pt\"><\/p>\n<div style=\"margin-bottom:0.8rem\">\n<li>Non-intrusive integration: Dry fog systems can be installed to complement existing airflow patterns without disrupting SMT operations.<\/li>\n<\/div>\n<p><\/span><br \/>\n<span style=\"font-size: 14pt\"><\/p>\n<div style=\"margin-bottom:0.8rem\">\n<li>Low-maintenance operation: Properly designed systems reduce the need for frequent cleaning or monitoring, helping teams focus on production rather than environmental troubleshooting.<\/li>\n<\/div>\n<p><\/span>\n<\/ul>\n<p><span style=\"font-weight: 400;font-size: 14pt\">These benefits make dry fog humidification particularly useful during seasonal swings when indoor humidity can drop rapidly and unpredictably.<\/span><\/p>\n<div class=\"text2 first\">\n<section>\n<div style=\"max-width: 824px;margin-left: auto;margin-right: auto\">\n<div style=\"margin-bottom: 0.8rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/10px-45px.svg') no-repeat 0 0;background-size: auto 30px;padding-left: 20px\">\n<h3 style=\"font-size: 1.5rem\">Monitoring and Maintenance Tips<\/h3>\n<\/div>\n<p><span style=\"font-weight: 400;font-size: 14pt\">To maximize the benefits of environmental control, consider the following<\/span><\/p>\n<p><span style=\"font-weight: 400;font-size: 14pt\">1. Continuous humidity monitoring: Deploy sensors at multiple points across the production floor to track relative humidity in real-time.<\/span><\/p>\n<p><span style=\"font-weight: 400;font-size: 14pt\">2. Targeted intervention: Focus humidification on areas with high-density boards or sensitive placement zones rather than broad, uniform application.<\/span><\/p>\n<p><span style=\"font-weight: 400;font-size: 14pt\">3. Regular system checks: Even precision systems can experience nozzle clogging or pressure drops over time. Scheduled inspection ensures consistent performance.<\/span><\/p>\n<p><span style=\"font-weight: 400;font-size: 14pt\">By combining monitoring with precision humidification, manufacturers can mitigate the seasonal effects of dry air and reduce the operational impact of static.<\/span><\/p>\n<div class=\"text2 first\">\n<section>\n<div style=\"max-width: 824px;margin-left: auto;margin-right: auto\">\n<div style=\"margin-bottom: 0.8rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/10px-45px.svg') no-repeat 0 0;background-size: auto 30px;padding-left: 20px\">\n<h3 style=\"font-size: 1.5rem\">Closing Thought<\/h3>\n<\/div>\n<p><span style=\"font-weight: 400;font-size: 14pt\">As SMT technology evolves, operational challenges like static and environmental variability will only become more critical. Addressing these factors proactively through targeted humidity control and informed monitoring supports consistent yield, compliance with stringent standards, and smoother production during seasonal swings.<\/span><\/p>\n<p><span style=\"font-size: 14pt\"><\/p>\n<h3>Access the Ikeuchi USA LinkedIn Newsletter Article Here:<\/h3>\n<p><\/span><\/p>\n<div style=\"text-align:center;margin-bottom: 3rem\">\n<iframe loading=\"lazy\" src=\"https:\/\/www.linkedin.com\/embed\/feed\/update\/urn:li:ugcPost:7384709022060470272?collapsed=1\" height=\"654\" width=\"504\" frameborder=\"0\" title=\"Embedded post\"><\/iframe>\n<\/div>\n<p><!-- \u4eba\u7269\u4ed8\u304d\u3010Product Information\u30dc\u30bf\u30f3\u3011\u3068\u3010Contact Us\u30dc\u30bf\u30f3\u3011\u3053\u3053\u304b\u3089 --><\/p>\n<div style=\"max-width: 824px;width: 100%;border-bottom: 1px solid #E9E9E9;margin: 3rem auto 3rem auto\"><\/div>\n<div style=\"max-width: 780px;margin-left: auto;margin-right: auto;margin-top: 4rem\">\n<div style=\"float: left\"><img decoding=\"async\" loading=\"lazy\" class=\"alignleft size-medium wp-image-5969\" src=\"https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/11\/call-1-s.jpg\" alt=\"\" width=\"308\" height=\"314\" \/><\/div>\n<div class=\"page-bottom_contacts\" style=\"float: right\">\n<div style=\"margin-left: auto;margin-right: auto\">\n<div style=\"line-height: 1.5;margin-bottom: 0.5rem;font-size: 1rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/check.svg') no-repeat 0 0;background-size: auto 20px;padding-left: 30px\">\n<ul>\n<li>Not sure which product is right for you?<\/li>\n<\/ul>\n<\/div>\n<div style=\"line-height: 1.5;margin-bottom: 0.5rem;font-size: 1rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/check.svg') no-repeat 0 0;background-size: auto 20px;padding-left: 30px\">\n<ul>\n<li>Curious about the total cost?<\/li>\n<\/ul>\n<\/div>\n<div style=\"line-height: 1.5;margin-bottom: 0.5rem;font-size: 1rem;background: url('https:\/\/www.dry-fog.com\/jp\/wp-content\/uploads\/sites\/2\/2024\/10\/check.svg') no-repeat 0 0;background-size: auto 20px;padding-left: 30px\">\n<ul>\n<li>Wondering where to start?<\/li>\n<\/ul>\n<\/div>\n<div style=\"line-height: 2;margin-bottom: 1.5rem;font-size: 0.8rem;font-weight: bold;padding-left: 30px\">\n<ul>\n<li>We\u2019re here to help \u2013 reach out with any questions.<\/li>\n<\/ul>\n<\/div>\n<div style=\"text-align: center\"><a class=\"content-ttl__sub\" style=\"margin-bottom: 1rem;justify-content: center;align-items: center;padding-top: 0.5rem;padding-bottom: 0.5rem;color: #fff;font-weight: 500;font-size: 1rem;background: #0C9B6F;border-radius: 30px\" href=\"https:\/\/www.dry-fog.com\/en\/products\/uni-hum-akimist-e\/\">Product Information<\/a><\/div>\n<div style=\"text-align: center\"><a class=\"content-ttl__sub\" style=\"justify-content: center;align-items: center;padding-top: 0.5rem;padding-bottom: 0.5rem;color: #fff;font-weight: 500;font-size: 1rem;background: #0C9B6F;border-radius: 30px\" href=\"https:\/\/www.dry-fog.com\/en\/contact\/\" target=\"_blank\" rel=\"noopener\">Contact Us<\/a><\/div>\n<\/div>\n<\/div>\n<div style=\"clear: both\"><\/div>\n<\/div>\n<p><!-- \u4eba\u7269\u4ed8\u304d\u3010Product Information\u30dc\u30bf\u30f3\u3011\u3068\u3010Contact Us\u30dc\u30bf\u30f3\u3011\u3053\u3053\u307e\u3067 --><\/p>\n","protected":false},"featured_media":0,"template":"","cat_technical_report":[134],"tag_technical_report":[462,420,461],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/technical-report\/8650"}],"collection":[{"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/technical-report"}],"about":[{"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/types\/technical-report"}],"wp:attachment":[{"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/media?parent=8650"}],"wp:term":[{"taxonomy":"cat_technical_report","embeddable":true,"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/cat_technical_report?post=8650"},{"taxonomy":"tag_technical_report","embeddable":true,"href":"https:\/\/www.dry-fog.com\/en\/wp-json\/wp\/v2\/tag_technical_report?post=8650"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}